PRODUCT Position:::HomePRODUCT—Neutral point gap grounding protection
a8469d9a29ba32fb5e000046d1e00be4
Neutral point gap grounding protection
110kV, 220kV, and 330kV are the main voltage levels in the power supply system, and their neutral points are generally grounded directly. Due to requirements for relay protection setting configuration and prevention of communication interference, as well as to limit single-phase short-circuit current, some transformers adopt a neutral point non-grounding method. Under this operation mode, lightning strikes, single-phase grounding short-circuit faults, etc. can cause overvoltage at the neutral point. Moreover, most transformers are graded insulated, so overvoltage poses a great threat to the insulation of the neutral point, and protective devices must be installed to prevent accidents.
15003226907 Consult Consult
Product Details
Neutral point gap grounding protection

ENR-JXB series transformer neutral point gap grounding protection complete set of equipment

1.Overview

110kV,220kV,and 330kV are the main voltage levels in the power supply system,and their neutral points are generally grounded directly.Due to requirements for relay protection setting configuration and prevention of communication interference,as well as to limit single-phase short-circuit current,some transformers adopt a neutral point non-grounding method.Under this operation mode,lightning strikes,single-phase grounding short-circuit faults,etc.can cause overvoltage at the neutral point.Moreover,most transformers are graded insulated,so overvoltage poses a great threat to the insulation of the neutral point,and protective devices must be installed to prevent accidents.

In China's 110kV-330kV power system,the neutral point protection of transformers primarily employs a parallel operation of lightning arresters and protective gaps.This constitutes the complete set of transformer neutral point gap grounding protection equipment,also known as the main transformer neutral point grounding assembly.

II.Model Description

 

b88bc60d84bf30ef21feef5565178c66

III. Working Principle

9e0b3a20b295c36002e0ceb0d6cda0d3

IV. Ordering Instructions 
1. Voltage level of transformer 
2. The transformation ratio, accuracy class, and capacity of the current transformer 
3. Rated current of the isolating switch and its operating mechanism type 
4. Is a pillar required

 

Previous:::Complete set of 330kV main transformer neutral point equipment Next:::Box-type substation